eventscribe

The eventScribe Educational Program Planner system gives you access to information on sessions, special events, and the conference venue. Take a look at hotel maps to familiarize yourself with the venue, read biographies of our plenary speakers, and download handouts and resources for your sessions.

close this panel
support

Technical Support


Phone: (410) 638-9239

Fax: (410) 638-6108

GoToMeeting: Meet Now!

Web: www.CadmiumCD.com

close this panel
←Back
‹‹ Go Back

Galen Cook-Wiens

Cedars Sinai Medical Center



‹‹ Go Back

Mourad Tighiouart

Cedars Sinai Medical Center



‹‹ Go Back

André Rogatko

Samuel Oschin Comprehensive Cancer Institute at Cedars-Sinai Medical Center



350 – Contributed Oral Poster Presentations: Biopharmaceutical Section

A Bayesian Adaptive Design for Cancer Phase I Trials Using a Flexible Range of Doses

Sponsor: Biopharmaceutical Section
Keywords: Cancer Phase I trials, Maximum tolerated dose, Escalation With Overdose Control, Dose limiting toxicity, Continuous dose, Flexible dose range

Galen Cook-Wiens

Cedars Sinai Medical Center

Mourad Tighiouart

Cedars Sinai Medical Center

André Rogatko

Samuel Oschin Comprehensive Cancer Institute at Cedars-Sinai Medical Center

We present a Bayesian adaptive design for dose finding in cancer phase I clinical trials. The goal is to estimate the maximum tolerated dose (MTD) after possible modification of the dose range during the trial. Parametric models are used to describe the relationship between the dose and the probability of dose limiting toxicity (DLT). We investigate model reparameterization in terms of the probabilities of DLT at the minimum and maximum available doses at the start of the trial. Trial design proceeds using escalation with overdose control (EWOC), where at each stage of the trial, we seek the dose of the agent such that the posterior probability of exceeding the MTD of this agent is bounded by a feasibility bound. At any time during the trial, we test whether the MTD is below or above the minimum and maximum doses, respectively. If during the trial, there is evidence that the MTD is outside the range of doses, we extend the range of doses and complete the trial with the planned sample size. At the end of the trial, a Bayes estimate of the MTD is proposed. We evaluate design operating characteristics in terms of safety of the trial design and efficiency of the MTD estimate. The methodology is further compared to the original EWOC design.

"eventScribe", the eventScribe logo, "CadmiumCD", and the CadmiumCD logo are trademarks of CadmiumCD LLC, and may not be copied, imitated or used, in whole or in part, without prior written permission from CadmiumCD. The appearance of these proceedings, customized graphics that are unique to these proceedings, and customized scripts are the service mark, trademark and/or trade dress of CadmiumCD and may not be copied, imitated or used, in whole or in part, without prior written notification. All other trademarks, slogans, company names or logos are the property of their respective owners. Reference to any products, services, processes or other information, by trade name, trademark, manufacturer, owner, or otherwise does not constitute or imply endorsement, sponsorship, or recommendation thereof by CadmiumCD.

As a user you may provide CadmiumCD with feedback. Any ideas or suggestions you provide through any feedback mechanisms on these proceedings may be used by CadmiumCD, at our sole discretion, including future modifications to the eventScribe product. You hereby grant to CadmiumCD and our assigns a perpetual, worldwide, fully transferable, sublicensable, irrevocable, royalty free license to use, reproduce, modify, create derivative works from, distribute, and display the feedback in any manner and for any purpose.

© 2014 CadmiumCD