This is the preliminary program for the 2003 Joint Statistical Meetings in San Francisco, California. Currently included in this program is the "technical" program, schedule of invited, topic contributed, regular contributed and poster sessions; Continuing Education courses (August 2-5, 2003); and Committee and Business Meetings. This on-line program will be updated frequently to reflect the most current revisions.

To View the Program:
You may choose to view all activities of the program or just parts of it at any one time. All activities are arranged by date and time.

The views expressed here are those of the individual authors
and not necessarily those of the ASA or its board, officers, or staff.


Back to main JSM 2003 Program page



JSM 2003 Abstract #301478
Activity Number: 9
Type: Invited
Date/Time: Sunday, August 3, 2003 : 2:00 PM to 3:50 PM
Sponsor: IMS
Abstract - #301478
Title: Physiological Noise in fMRI
Author(s): Gary Glover*+
Companies: Stanford University
Address: Lucas MRS Bldg. P264, Stanford, CA, 94305-5488,
Keywords: functional MRI ; physiological noise ; denoising
Abstract:

Functional MRI experiments employ statistical methods to test for activation because the BOLD contrast is often comparable to the noise. The noise includes components from thermal sources in the head, RF coil and associated electronics, as well as from fluctuations in the NMR signal. These fluctuations result from instrument instabilities that modulate the signal as well as physiological contributions from the subject, with the latter dominating, especially at higher fields. The physiological components in turn are caused by cardiovascular-induced pulsatility, respiration induced modulations in the magnetic field and fluctuations in blood flow/volume due to basal metabolism and autonomic hemodynamic regulation. Respiratory effects are pernicious because they cause breathing-correlated movement of EPI images in the phase encoding direction. This talk reviews these factors and examines methods developed to reduce the effects of several of these physiological noise sources. These correction methods include retrospective correction for cardiac and respiratory modulation in image space and k-space as well as prospective correction for respiration.